Skip to Main Content
Home
About Us
My Account
Contact Us
Blog
Login
Register
home
Shopping Cart
0
Items -
$0
0
Items
Toggle navigation
MRI Safety
Ferromagnetic Detection
MRI Safety Signs
MRI Safety Floor Signs
MRI Safety Labels
MRI Fire Extinguishers
MRI Training and Books
Metal Detection
Oxygen Deficiency Monitoring
MRI Phantoms and Cradles
MRI Transport
MRI Safe Wheelchairs - Plastic MRI Safe
MRI Wheelchairs - Non Ferromagnetic Wheelchairs
MRI Wheelchairs - Non Magnetic
MRI Transport Chairs - Non Magnetic Transport Chairs
MRI Stretchers - Non Ferromagnetic Stretchers
MRI Stretchers - Non Magnetic Stetchers
MRI Walkers and Gait Belts
MRI Transfer Boards
MRI Transport Accessories
MRI Transport Replacement Parts
Comfort
Patient Comfort Positioning Pads
Columbus Healthcare Products Positioning Pads
Foam Positioning Pads
Pearltec Inflatable Positioning MultiPads
Pearltec Foam Positioning Pads
MRI-Earplugs
MRI Ear Protection
MRI Disposable Headset Covers
MRI Eyewear
MRI Headsets
MRI Sound Systems
Vacuum Immobilizers Infant and Child
Scan-Bands Security Straps
KyphoWedge
Monitoring
MRI Electrodes
MRI Patient Monitoring Equipment
MRI Stethoscopes and Sphygsmomonometers
Respiratory
MRI Cylinder Holders & Carts
MRI Cylinders
MRI Flowmeters
MRI Regulator Flow Meter Combinations
MRI Regulators
MRI Suction Systems
Procedures
MRI Laryngoscopes
MRI Biopsy
MRI Titanium Insturments
Infection Control
MRI Cleaning & Janitorial
MRI Sanitary Covers
Furniture
MRI Doctors Stools
MRI Linen Carts
MRI Linen Hampers
MRI Mobile Cabinets
MRI Utility Carts
MRI Organization and Office Supplies
MRI Lighting
MRI Privacy Screens
MRI Procedure Carts
MRI Stands and IV Poles
MRI Step Stools
MRI Tables & Mayo Stands
MRI Waiting Room Furniture
MRI Furniture Replacement Parts
MRI Ladders and Stands
MRI Tools
MRI Scanner Testing
MRI Titanium Tools
MRI Tools Sets
Home
MRI Tools
MRI Scanner Testing
ACR MRI Phantom Large
Zoom in on Image(s)
ACR Test Phantom - ACR-PH1
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Email a friend
ACR MRI Phantom Large - PH1
0/5 rating
0
Review(s)
Write a Review
Your Price:
$2,400.00
The ACR MRI Phantom is an 8" (203.2 mm) diameter cylinder, 6.82" (173.40 mm) tall with various fixtures inside, including a grid, cylinders, and other points of interest. Marked with reference points for nose and chin. The Phantom is approved by the American College of Radiology.
Questions about this item? Ask here.
Part Number:
03-10090-ACR
Put me on the Waiting List
Quantity
+
-
Add to Cart
Submit
product tabs
Description
Questions and Answers
Specifications
Supporting Documentation
ACR Large MRI Phantom - ACR-PH1
The MRI ACR Phantom Large, is a high-precision diagnostic instrument developed to support MRI system calibration and quality assurance in accordance with American College of Radiology (ACR) standards. Designed to ensure consistent image quality and reliable system performance, this advanced phantom plays a vital role in maintaining regulatory compliance. Manufactured from durable materials and built to exacting specifications, it enables technicians and radiologists to perform critical imaging evaluations, including spatial resolution, contrast accuracy, and image uniformity. The MRI ACR Phantom is an essential tool for optimizing MRI performance, identifying potential system issues, and upholding the highest levels of diagnostic accuracy and patient care.
Features:
Geometric distortion
Points of reference
Slice thickness and position
Interslice gap
Physical and electronic slice offset
Spatial resolution
Low contrast detectability
Image uniformity
Signal-to-noise ratio (SNR)
Image bandwidth
Bandwidth: water-fat shift
Complies with: ACR MRI Accreditation Program Regulations
Q:
Is this a medical item?
Asked by:
Dia
- 7/23/2025
A:
MRI phantoms are not classified as medical devices. While they are used in the testing, calibration, and quality assurance of medical imaging systems, they themselves do not serve a direct medical purpose. Specifically, they do not perform any of the following functions:
1. Diagnosis, prevention, monitoring, treatment, or alleviation of disease;
2. Diagnosis, monitoring, treatment, alleviation of, or compensation for an injury;
3. Investigation, replacement, modification, or support of the anatomy or of a physiological process for medical purposes.
Was this answer helpful?
0 of 0
Customer(s) found this Answer helpful.
Answer provided by:
Eric (7/23/2025)
1
Questions about this item? Ask here.
1
Specifications -
ACR-PH1 -
MRI Large Phantom
DIAMETER: 8.00" (203.2mm)
HEIGHT: 6.82" (173.4mm)
LEVEL BAR - LENGTH: 7.00" (177.8mm) WIDTH: .375" (9.53mm)
Filling: Solution of nickel chloride and sodium chloride
MRI Large Phantom Data Sheet
MRI Large Phantom SDS Cover Sheet
MRI Large Phantom SDS